R/F MEASUREMENTUsing R/F, RAD, Dose or DENT version.For best accuracy, center the selected sensor field (R/F low, R/F high, RAD, DENT low or DENT high)

Page 3 - CONTENTS

2. MEASURE MODEAfter an oset adjustment, the instrument is in MEASURE MODE. The displayed values are updated after each exposure, or continuously aft

Page 4

All values are stored in a non-volatile memory and are valid until manually changed. At start up (after the battery status information), valid Trig de

Page 5 - INTRODUCTION

MAMMOGRAPHY MEASUREMENT Place the detector along the X-ray tube axis (with the cable end pointing towards the X-ray machine). Make sure that the cente

Page 6 - THE RAYSAFE SOLO

Dose rate Gy or R per s, m or hTime ms, sHVL mm Al (only with optional HVL kit)3. SETUP MENUPress SELECT to enter the SETUP MENU (from MEASURE MODE) a

Page 7 - EASY TO USE

Auto Power ONever, or after 5, 20 or 60 minutes of inactivity.Info Displays the serial number (S/N) and firmware version of the connected detector and

Page 8 - GETTING STARTED

CT MEASUREMENTThe RaySafe Solo CT detector is an ion chamber with a 10 cm active length and a built-in bias voltage. The center and the edges (+ 5 cm

Page 9 - BATTERY AND CHARGER

1. SENSOR MENUCT Dose Ion chamber sensorPress STEP to step between sensors and SELECT to select a sensor.NOTE! When turning on the base unit with th

Page 10 - R/F MEASUREMENT

Calc. delay Defined as the dead time after end trig, before data is calculated. Default is 0.5 s but it is recommended to use a longer delay when measu

Page 11

LIGHT MEASUREMENTThe RaySafe Solo light detector is designed to measure luminance on LCD and CRT monitors, as well as light boxes, and illuminance for

Page 12

© 2013.01 Unfors RaySafe 5001053-CAll rights are reserved. Reproduction or transmission in whole or in part, in any form or by any means, electronic,

Page 13 - MAMMOGRAPHY MEASUREMENT

Press STEP when in MEASURE MODE to freeze and move the measured value to the second line of the display. A new press on STEP will move a new measured

Page 14

All values are stored in a non-volatile memory and are valid until manually changed.(Factory settings in bold.)Oset adjustment To ensure the highest

Page 15

mA/mAs MEASUREMENTNOTE! It is possible to measure mAs simultaneously with other measurements with RaySafe Solo R/F. The instrument will trig on rad

Page 16 - CT MEASUREMENT

2. MEASURE MODEAfter an oset adjustment, the instrument is in MEASURE MODE. The displayed values are updated after each exposure or continuously afte

Page 17

Info Displays the serial number (S/N) and firmware version of the detector and the RaySafe Solo base unit and the calibration date for the selected sen

Page 18

PASSIVE mAsIt is possible to measure mAs simultaneously when using the RaySafe Solo R/F with mAs. The instrument will trig on radiation, not on the cu

Page 19 - LIGHT MEASUREMENT

MEASUREMENT DEFINITIONSFigure 1 illustrates the RaySafe Solo parameter definitions available on a typical waveform. In most situations the default sett

Page 20

The dose is accumulated from the start trig point plus Trig delay until the end trig.Figure 2. Trig delay activatedNOTE! The trig level setting (25,

Page 21

DOSE RATEThe RaySafe Solo calculates dose rate as dose/exposure time if the exposure time is less than 6 seconds.After an exposure longer than 6 secon

Page 22

Figure 4. kV and kVpTable: Active compensation on kV measurementsSENSOR FILTRATION kV/KVpR/F low Max. 15 mm Al kVR/F high RAD Max. 15 mm Al kVp (when

Page 23

CONTENTSINTRODUCTION ... 5Versions ...

Page 24

Figure 5. 75 % trig level activated (figure also applies to 25 and 50 % trig level settings). Please note that the trig level setting aects the do

Page 25 - PASSIVE mAs

HVL is an indication of the beam quality and is defined as the amount of Al filtration, measured in mm, needed to reduce the dose in half. HVL is kVp de

Page 26 - MEASUREMENT DEFINITIONS

RAYSAFE SOLO PC KITThe optional RaySafe Solo PC kit contains:• RaySafe Xi View software• serial cable• serial to usb converter• optional: bluetoot

Page 27

TRANSFER DATA TO A COMPUTERTo view the waveform in the RaySafe Xi View and/or transfer measured data to a PC, connect a serial cable or Bluetooth modu

Page 28 - DOSE RATE

7. Start RaySafe Xi View and go to File – Settings and enter the correct COM port. Press the Start button and “Started waiting for data” will appear

Page 29

ACCESSORIESTHE RAYSAFE FLEXI STANDThe RaySafe flexi stand can be used in many dierent ways. Assemble it to fit your needs.THE RAYSAFE OPG HOLDER1. If

Page 30

4. Expose and align the fluorescent line with the preferred black line (selected sensor) on the alignment lid. Soften the lighting if needed and compl

Page 31 - TOTAL FILTRATION  OPTIONAL

TIPS AND TRICKSARRANGEMENT OF MEASUREMENTMake sure nothing is in the X-ray field when measuring with the RaySafe Solo.The fact that the dose is proport

Page 32 - RAYSAFE SOLO PC KIT

VERTICAL DETECTOR PLACEMENTWhen measuring on a mammography machine with a horizontal beam, such as MultiCare Platinum, let the pressure from the compr

Page 33 - INSTALLING RAYSAFE Xi VIEW

DISPLAY MEANINGt<delay The exposure time is not long enough to calculate a value.Ofl. Overflow, i.e. calculated value is numerically higher than can

Page 34 - GETTING HELP

Setup of Bluetooth communication ... 33Getting help ...

Page 35 - ACCESSORIES

I sometimes get readings which are far o expected when measuring with RaySafe Solo DENT on panoramic X-ray machines, why?Most likely the detector’s s

Page 36 - THE RAYSAFE CASSETTE HOLDER

What happens if the mA/mAs cable is connected with the wrong polarity?The RaySafe Solo will not show any mA/mAs readings. As long as the mA/mAs cable

Page 37 - TIPS AND TRICKS

The RaySafe Solo detector end trigs during exposure.Make sure to select an appropriate Calc. delay if using the instrument with pulsed generators, or

Page 38 - DISPLAY CODES

WARRANTY, SERVICE AND SUPPORTUnfors Raysafe warrants to the original product purchaser that each product it manufactures will be free from defects in

Page 39 - FREQUENTLY ASKED QUESTIONS

DISPOSALThe Directive on Waste Electrical and Electronic Equipment (WEEE)This symbol, found on the product or on its box, indicates that this product

Page 40

INTRODUCTIONVERSIONSThis user manual covers the following articles:base unit version: 8221011 detector version: 82220158221022 82220168222017822201882

Page 41 - TROUBLESHOOTING

THE RAYSAFE SOLOThe RaySafe Solo consists of a base unit and a detector.Communication between detector and base unit is purely digital, thereby minimi

Page 42

EASY TO USEThe RaySafe Solo is very easy to use.The built-in active compensation automatically applies corrections for dierent beam qualities, filtrat

Page 43 - WARRANTY, SERVICE AND SUPPORT

GETTING STARTED1. Connect the detector to the base unit with one of the two (2 and 10m) cables. 2. Position as required for the detector, see the fo

Page 44 - DISPOSAL

BATTERY AND CHARGERThe RaySafe Solo base unit has a chargeable 7.4 V Li-ion battery, providing approximately 20 – 40 hours of operation (depending on